Welding Refrigeration Air Conditioning Lines

Welding Refrigeration Piping on Air Conditioning Systems Properly.

I have checked out several short articles, as the majority of them claim that copper lines should be soldered with silver-based substances or low-temperature level brazed with copper-based compounds. Due to the high melting point of these soldering/brazing substances, the lines must be expunged with inert gasses (such as nitrogen) to stop oxides forming in the tubes. All the above makes sense except if jointing tubing can be accomplished at lower temperatures, the requirement for high heat as well as nitrogen expunging could be removed. This appears like a vital benefit (if the top quality of the joint can be ensured). Suppose reduced temperature level soldering could do the job? What if for the mass-produced products, joining of plumbing system could be completed in a low-temperature furnace (say 500 degrees F)? I’ve also review records of air conditioning and refrigeration professionals admitting to soft soldering joints to save expenses.”.

brazing-refrigerant-air-conditioning-pipingI wish to provide some thoughts. Soldering is a viable technique of signing up with air conditioning and refrigeration tubes and parts while servicing and also setting up refrigeration systems. However, not all sorts of solders can be utilized sufficiently. Tin-lead, as well as tin-antimony alloys, are not usually suggested for our systems. They do not provide the needed toughness and ductility. Nevertheless, a tin-silver blend is a viable choice and also provides some distinctive benefit over brazing.

Some advantages consist of the elimination of oxide scale developed by heating the joint. This indicates a nitrogen purge is not called for during this process – which is an excellent conserving for any sort of service technician. Not only will a specialist save money on the expense of the nitrogen; there is additionally a definite plus in not having to carry the nitrogen cylindrical tube to the job. Another advantage of the use of a tin/silver blend solder is the lantern. A smaller sized torch head with much less warmth could be utilized sufficiently to solder the joint, indicating lighter and fewer tools to bring to the job site. Much less warmth likewise suggests less possibility of damaging elements throughout the heating procedure, such as growth valves as well as solenoids.

There is one exemption to using a tin/silver blend. Its applications are restricted to solution temperatures of much less compared to approximately 200 degrees. When solution temperature levels exceed this, valve brazing may be a far better option.

Another worry when selecting whether to braze or solder is the producer of the tools being serviced. It is usually perfectly to adhere to a supplier’s referral. Producers generally tend to be quite traditional in their referrals as well as might suggest brazing over soldering for servicing their systems.

Here is an advised treatment for soldering air conditioning and refrigeration tubing and elements:

copper-brazing-air-conditioning-condensor-coilAction, cut, deburr, tidy, and also apply the correct change to the tubes. Make sure the flux made use of is defined for the type of filler steel being utilized. When applying the flux, use it to the male fitting just, use it moderately, as well as do not apply flux throughout of the male installation. Preferably, revolve the male suitable 1/4 turn when putting it into the women joint. Apply the fire to the joint. Heat the male tube near the joint initially, then relocate to the women suitable. Ensure the lantern moving in order to uniformly heat the parts as well as to stop overheating any type of one area.

Relocate the flame away from the joint and then touch the solder to the joint. If the solder does not thaw on contact with the joint, eliminate it and also continuously heat up the joint then try once again. Do not thaw the solder with the flame.

When the joint temperature is hot sufficient to melt the solder, apply warmth to the base of the suitable to pull the solder into the joint. Continue to feed the solder till a ring of solder shows up around the joint. After the joint is made, allow it to cool then rub away any residue change. Do not permit any of the change to continue to be on the joint as it is destructive and may trigger future issues. Remember, soldering is a feasible alternative for air conditioning and refrigeration specialists while servicing and mounting refrigeration systems. Sometimes, it will certainly make signing up with ACR tubes and also parts a lot easier process.